10kV grounding switch

The JN15-12/31.5-210 series indoor high-voltage earthing switch (hereinafter referred to as the “earthing switch”) is a new type of earthing switch developed by our company through the introduction of advanced foreign technologies and in response to market needs. It is suitable for use in indoor 3–40.5 kV three-phase AC power systems operating at 50 (60) Hz, and can be paired with various models of high-voltage switchgear. It may also be used for earthing purposes during maintenance of high-voltage electrical equipment. Comprehensive testing has demonstrated that its performance complies with the requirements of GB 1985 “AC High-Voltage Isolating Switches and Earthing Switches” and IEC 129.
Keywords:

Product Overview

The JN15-12/31.5-210 series indoor high-voltage earthing switch (hereinafter referred to as the “earthing switch”) is a new type of earthing switch developed by our company through the introduction of advanced foreign technologies and in response to market needs. It is suitable for use in indoor 3–40.5 kV three-phase AC power systems operating at 50 (60) Hz, and is designed to be paired with various models of high-voltage switchgear. It can also be used for earthing purposes during maintenance of high-voltage electrical equipment. Comprehensive testing has demonstrated that its performance complies with the requirements of GB 1985 “AC High-Voltage Isolating Switches and Earthing Switches” and IEC 129.


Working conditions

● Applicable to the following environments

The elevation shall not exceed 1,000 meters;
Ambient temperature shall not exceed +40°C or fall below -10°C;
The daily average relative humidity shall not exceed 95%, and the monthly average shall not exceed 90%.
Seismic intensity shall not exceed 8 degrees;
● Not applicable to the following venues
The installation location is subject to gases, vapors, chemical precipitates, dust and dirt, as well as explosive and corrosive substances that can severely impair the insulation and conductivity of the earthing switch; furthermore, the installation location experiences frequent and severe vibrations.


Implementation Standard

GB1985


Technical Specifications

Main Parameters Product Model

Rated voltage
(KV)

4S thermal stability current
(KA)

Dynamic stability current
(Peak KA)

Closing current
(Peak KA)

Rated Insulation Level
(Power-frequency withstand voltage / impulse withstand voltage, kV)

Center of the pole gap
(mm)

JN15-12/31.5-150

12

31.5

80

80

42/75

150

JN15-12/31.5-165

12

31.5

80

80

42/75

165

JN15-12/31.5-180

12

31.5

80

80

42/75

180

JN15-12/31.5-200

12

31.5

80

80

42/75

200

JN15-12/31.5-210

12

31.5

80

80

42/75

210

JN15-12/31.5-220

12

31.5

80

80

42/75

220

JN15-12/31.5-230

12

31.5

80

80

42/75

230

JN15-12/31.5-250

12

31.5

80

80

42/75

250

JN15-12/31.5-275

12

31.5

80

80

42/75

275


External Dimensions Table

Product Model

E

F

G

H

D

JN15-12/31.5-150

150

75

160

535

396

JN15-12/31.5-165

165

75

160

565

426

JN15-12/31.5-180

180

75

160

595

456

JN15-12/31.5-200

200

50

185

635

496

JN15-12/31.5-210

210

50

185

655

516

JN15-12/31.5-220

220

50

185

675

536

JN15-12/31.5-230

230

50

185

695

556

JN15-12/31.5-250

250

50

185

735

596

JN15-12/31.5-275

275

50

210

810

646

Outline Dimension Drawing (mm)