Indoor high-voltage vacuum circuit breaker

The VS1 (ZN63)-24 series indoor high-voltage vacuum circuit breaker is an indoor high-voltage switchgear with a rated voltage of 24 kV and a three-phase AC frequency of 50 Hz. It is suitable for use as a control and protection switch in power transmission and distribution systems at power plants, substations, and industrial and mining enterprises, particularly in high-altitude areas where it is required to interrupt critical loads and perform frequent operations. The circuit breaker is manufactured in accordance with China’s national standards GB 1984-2003 “AC High-Voltage Circuit Breakers,” DL/T 403-2000 “Technical Specifications for Ordering Indoor Vacuum Circuit Breakers Rated 3.6–40.5 kV,” as well as relevant IEC standards, and features reliable interlocking functions. The operating mechanism of the circuit breaker is spring-energy-storage type, supporting both AC and DC energy storage operation, as well as manual operation.
Keywords:

Product Overview

The VS1 (ZN63)-24 series indoor high-voltage vacuum circuit breaker is an indoor high-voltage switchgear with a rated voltage of 24 kV and a frequency of 50 Hz for three-phase AC. It is suitable for use as a control and protection switch in transmission and distribution systems at power plants, substations, and industrial and mining enterprises, and is particularly well suited for applications in high-altitude areas where critical loads are switched and frequent operations are required.
The circuit breaker is manufactured in compliance with China’s national standards GB 1984-2003 “AC High-Voltage Circuit Breakers” and DL/T 403-2000 “Technical Specifications for Ordering Indoor Vacuum Circuit Breakers Rated 3.6–40.5 kV,” as well as relevant IEC standards, and features reliable interlocking functionality.
The circuit breaker’s operating mechanism is spring-energy-storage type, supporting both AC and DC energy storage operation as well as manual operation.
The circuit breaker can also be equipped with a long-life permanent-magnet operating mechanism, boasting a mechanical life of up to 10,000 operations, making it suitable for applications involving extremely frequent switching.
The circuit breaker is designed with a front-and-back modular structure, allowing it to be used either as a fixed-mounted unit or in combination with a chassis truck to form a center-mounted unit.


Terms of Use

● Altitude: not exceeding 2000 m

● Ambient temperature: maximum +40°C; minimum -15°C

● Ambient humidity: Daily average relative humidity: ≤ 95%; Monthly average relative humidity: ≤ 90%

● Earthquake intensity: less than 8 degrees

● Use in locations free from dripping water, fire hazards, explosion risks, severe contamination, chemical corrosion, and violent vibration.


Product Features

● Adopts a next-generation modular spring-operated mechanism, featuring a compact and simple structure, rational layout, reliable transmission, and convenient installation;
● Integrated design of the operating mechanism and the circuit breaker body; it can be used as a fixed installation unit or, when equipped with a dedicated pusher mechanism, configured as a handcart unit.
● The main electrical circuit shall primarily utilize insulated cylinders; alternatively, a solid-sealed pole configuration may be adopted.
● The circuit breaker is an E2-class circuit breaker;
● Comprehensive five-protection interlocking functions after cabinet assembly.


Technical Specifications

Project

Unit

Parameters

Rated voltage

kilovolt

24

Rated frequency

Hertz

50

Rated current

A

630

1250

1600

Rated short-circuit breaking current

kA

20

25

31.5

Rated short-circuit making current (peak)

kA

50

63

80

Rated short-circuit duration

S

4

Rated short-circuit breaking current breaking operations

times

20

Rated Operating Sequence

 

O-0.3s-CO-180s-CO

Rated Lightning Impulse Withstand Voltage (Across Break)

kilovolt

125

Rated 1-min power-frequency withstand voltage (interrupting gap)

kilovolt

65

Closing time

milliseconds

≤100

Trip time

milliseconds

≤50

Mechanical life

times

20000

Rated Energy Storage and Operating Voltage

V

~220/110

Breaking time

milliseconds

≤65

Storage time

S

≤10

 

Mechanical characteristic parameters of circuit breakers

Project

Unit

Parameters

Contact opening distance

mm

13±1

Contact overtravel

4±1

Center distance between electrodes

275

Permitted contact wear thickness

3

Average opening speed (after 6 mm of initial separation)

m/s

13 ± 0.3

Average closing speed

0.6±0.2

Contact closing bounce time

milliseconds

≤2

Three-pole closing and opening synchronism

≤2

Main circuit resistance

Rated current

kilovolt

630

1250

1600

2000

2500

3150

Fixed

microohm

≤50

≤45

≤35

≤35

≤30

≤25

Handcart type

≤55

≤50

≤40

≤40

≤35

≤30

Trip time

milliseconds

≤50

Closing time

≤75

Operating mechanism operating characteristics

85%~110% rated voltage

Reliable closing

65%~120~rated voltage

Reliable trip

≤300/rated voltage

No trip allowed


External mounting dimensions

Get a Quote

Through the previous introduction, we believe you have learned enough about us and are confident to cooperate with us. Please leave your information quickly, We will contact you within 24 hours!

Submit

Get a Quote

Through the previous introduction, we believe you have learned enough about us and are confident to cooperate with us. Please leave your information quickly, We will contact you within 24 hours

Submit